Author:
Lichtenstein, N.; Stockmann, R.; Bogdoll, B.; Hosseinpour, J.; Jaeger, K.; Kieper, H.; Linde, H.; Schramm, K.
Title:
Interlaboratory trial for measuring polychlorinated dibenzodioxins and -furans in workplace air
Source:
Gefahrstoffe - Reinhalt. Luft 56 (1996) No. 6, pp. 239-245, 11 fig., 6 tab., 8 lit.-ref. (Language:D)
Abstract
Six simultaneous samplings were carried out in an aluminium recycling plant to validate a method for determining the concentration of polychlorinated dibenzodioxines and -furans (PCDD/PCDF) in workplace air. The sampling device was developed in the "Berufsgenossenschaftliches Institut für Arbeitssicherheit" (BIA) and is able to sample particulate PCDD/PCDF according to the total dust definition using a glass fibre filter and filter-passing PCDD/PCDF using a layer of polyurethane foam. The samples were analysed in six different laboratories, which were allowed to use different analytical methods. The relative standard deviation for the results is 25%. This satisfies the requirements of DIN EN 482 for the performance of procedures for measuring chemical agents.