Number of publication:   081/1993-BIA
Author:   Heidermanns, G.; Lichtenstein, N.; Kühn, L.; Riepe, W.
Title:   Quartz
Source:   In: Analytische Methoden zur Prüfung gesundheitsschädlicher Arbeitsstoffe. Volume I: Luftanalysen, Meth.-Nr. 1, 8th suppl. 1993, 15 pages, 24 lit. refs., 1 table, 2 figs. Published by: Henschler, D. DFG Deutsche Forschungsgemeinschaft. Wiley-VCH, Weinheim 1976 - loose-leaf edition. ISBN: 3-527-27636-X (Language:D)
Abstract
Preseoparators serve to collect fine dust on membrane filters. After incineration of filter material and preparation of the non-burned residue by means of hydrochloric acid, the remaining substance is applied, as a sufficiently thin layer, on a silver filter. The quartz concentration is then determined using on x-ray diffractometer following the method of external standard. As a result of a modification of the x-ray diffractometric method (thin layer method) it is now possible to carry out a quartz analysis by only one single intensity measurement. This method can be used for determining fine dust concentrations of quartz in the workplace atmosphere.

Back to overview